ATA 47 - INERT GAS SYSTEM
- The Fuel Tank Inerting System (FTIS) includes two sub-system- The Conditioned Service Air System (CSAS),&The Inert Gas Generation System (IGGS).
- If the oxygen sensor senses an oxygen rate higher than 12%, the ICUde-energizes the IGGS Isolation Gate Valve solenoid and the DFSOV solenoid to close the IGGS Isolation Gate Valve and the DFSOV.
- The FTIS does not operate on the ground, located on pack 1 compartment.
- Engine 1 is the primary bleed source and Eng 2, through the X-Bleed valve, is the
secondary bleed source.